SeriePT-PS

Measuring ranges: 4 l/h … 50 m3/h H2O at 20ºC, 120 Nl/h … 1500 Nm3/h air at 1 bar abs, other scales on request.  Accuracy: PT/PS models +-4% f.s. PTM/PSM models +-6% f.s. Connexions: DIN DN15 … DN80 flanges, threaded fittings from ½” to 3” BSP, PVC solvent weld socket fittings,  SS fittings for welding, others on request, Materials: Flow tube: Trogamid T, Polysulfone and NAS, wetted parts/fittings: PVC, EN 1.4404 (SS 316L), Steel, PP. Other on request. Local indication. Options: 1 or 2 adjustable reed switches, 4-20 mA transmitter (max. resolution 18 points), HART ™ protocol, Profibus, Fieldbus on request.

Serie-2000

Measuring ranges: 0,1 l/h … 1000 l/h H2O, 1Nl/h … 30 Nm3/h air. Accuracy: 2100 model ±3,5% f.s., 2150 model ±3% f.s.,  2300/2340 models ±1,6% f.s. Connections: 2100/2150/2300 models 1/4” BSP, NPT, 2340 model 1/2” or 3/4” M BSP, NPT, Materials: Flow tube: borosilicate glass, Wetted parts: EN 1.4404 (SS 316L), Float: EN 1.4404 (SS 316L), glass, plastic, ceramic. Local indication. Options: 1 or 2 adjustable switches (optical detector, inductive sensor or reed switch), constant flow regulator
RCD or RCA, without valve.

Serie-6000

Measuring ranges: 2,5 l/h … 40 m3/h H2O,  40 Nl/h … 1200 Nm3/h air.     Accuracy: +-1,6% f.s.  Connections:  DIN DN15 … DN80 flanges, Threaded fittings from ½” … 3” BSP, PVC solvent weld socket fittings,  SS fittings for welding, others on request.  Materials: Flow tubes: borosilicate glass, length 300 mm.  Wetted parts: Coated steel, EN 1.4404 (SS316L), PVC, PP, PTFE. Options: 1 or 2 adjustable reed switches, 4-20 mA transmitter (max. resolution 18 points), HART ™ protocol, Profibus, Fieldbus on request.

Serie-m21

Suitable for vertical upwards flow. Aluminium box: Avaible in AISI 316L under request  Measuring ranges: 0,4 l/h … 1000 m3/h H2O,  12 Nl/h … 30Nm3/h air.  Accuracy: +-4% f.s.  Connections:  1/4” … 3/4” BSP, NPT, DN10 … DN25 sanitaria. Materials: EN. 14404 (AISI316L). Options: Regulating valve, Design for high pressure on request , 1 or 2 adjustable inductive switches, Electronic transmitter with 4-20 analog output 2 wires, Ex version on request, constant flow regulator RCD or RCA

Serie-SC250

Available for all flow directions. Indicator housing in aluminium: Available in SS 316L or PP on request. Measuring ranges: 2,5 l/h … 180 m3/h H2O, 75 Nl/h … 5500 Nm3/h air. Accuracy: +-2,5% f.s. (+-1,6% f.s. on request). Connections: Model SC250: DN15 … DN150, threaded connections BSP or NPT, sanitary connections according to ISO 2852, SMS 1145, DIN 11851, TRI-CLAMP®. Materials: SS 316L, PVC, PP, PTFE, Titanium, Hastelloy C. Options: 1 or 2 adjustable switches (micro-switch or inductive sensor), design for high pressure on request, Electronic transmitter with 4-20 analog output for safe or hazardous area (Ex ia IIC T4 or T6 protection). HART ™ protocol on request. Local volume totalizer. Remote volumen totalizar by means of pulse output (not available for Ex transmitters).

Serie-PR

Indication by means of by-pass flowmeter. Materials: EN 1.4404 (SS 316L), PVC, PP, … others on request. Measuring ranges: 2 m3/h … 20000 m3/h H2O, 30 Nm3/h … 300000 Nm3/h air. Accuracy: +-4% f.s. Connections: DN50 … DN1000, orifice plate mounted between flanges,  flowmeter fittings threaded, flanged or solvent weld socket, pressure inlets ¾” BSP. Local indication. Options: 1 or 2 adjustable switches (different options according to by-pass flowmeter), 4-20 mA output, Ex version on request, according to transmitter model, HART ™ protocols, Profibus, Fieldbus on request, according to transmitter model.

Serie-DP

Available for all flow directions. Measuring range: 0,8 m3/h … 1600 m3/h H2O,  45 Nm3/h … 24000 Nm3/h air.  Accuracy: DP65 model +-2,5% f.s. (+-1,6% f.s. on request).  Connections:  DP65 model DN40 … DN300 between flanges . Materials:  Coated steel, EN 1.4404 (SS 316L).  Housing: Aluminium, Available in SS 316L or PP on request.  Local indication.  Options: 1 or 2 adjustable switches (micro-switch or inductive sensor),  Design for high pressure on request,  Electronic transmitter with 4-20 analog output for safe or hazardous area (Ex ia IIC T4 or T6 protection, ATEX certified).  HART ™ protocol on request, Local volume totalizer. Remote volume totalizer by means of pulse output (not available for Ex transmitters).

Serie-TM

Measuring range: 300 l/h … 1100 m3/h H2O,  Accuracy: +-0,5%. Connexions: DN15…DN50 PN40,  DN10…DN500 PN16, Standard flange connection according to DIN2502 flanges, Others on request,  BSP o NPT threaded connections, DIN11851 sanitary connection.  Materials: Body: EN 1.4404 (SS 316L). Propeller: EN 1.4416 (SS 430).  Output Signal: mV output by means of pick-up coil proportional to the flow. Compatible with associated electronic converters: CIP / CP / MC / MT / DFD / APTM series, Others on request. Considered as “Simple Aparatus” according to ATEX.  Options:  Design for high pressure on request, Special design for converters from different manufacturers.

Serie-COVOL

Measuring range: 10 l/h … 60 m3/h H2O. Accuracy: +-0,8%.
Connections: DIN2501 flanges DN10…DN100,  Others on request, BPS or NPT threaded  connections, Sanitary connections according to DIN 11851, Clamp ISO 2852… Others on request.  Materials: Body: EN 1.4404 (SS 316L), PVC, PP & PTFE  Piston: PTFE-graphite, Aluminium, Bronze, PVDF.  Viscosity up to 120000 cP.  Reed switch pulse output.  Compatible with associated electronic converters: CIP / CP / MC / MT / DFD / APTM series, Others on request. Considered as “Simple Aparatus” according to ATEX.  Options:  Design for high pressure on request,  Special design for converters from different manufacturers, Heating-cooling chamber on request.

Serie-FLOMID..

Suitable for flow measurement of liquids with conductivity higher than 20 uS/cm. Measuring range: 10 l/h … 7000 m3/h H2O.  Accuracy: +-0,5%. Connections: DN3 … DN500, others on request, DIN or ANSI flanges, Between flanges DIN or ANSI flanges, Sanitary connection, Others on request. Materials:  Body: EN 1.4404 (SS 316L) Liner: PP, PVDF, Ebonite & PTFE.  Electrode: Hastelloy C, EN 1.4404, Zr, Ti and Tantalum. Output: 4-20 mA / 0 … 1000 Hz,  Totalizer,  Flow indication, Batching.
Options: High pressure design on request (only for flange connection), Other flange standard on request.  HART ™ protocol on request

Serie-FLOMAT

Suitable for flow measurement of liquids with conductivity higher than 20 uS/cm. Measuring range:  2 m3/h … 113000 m3/h H2O.  Accuracy: +-3,5%. Connections: DN40 … DN2000 TF o DIN Flange, 2 ¼” BSP Threaded. Body: EN 1.4404 (SS 316L), PVDF. Sensor head: PVDF.  Electrodes: Hastelloy C, EN 1.4404, Zr, Ti and Tantalum. Output: 4-20 mA /0 … 1000 Hz,  Totalizer,  Flow indication. Options: High pressure  design on request (only for flange connection), Other flange standard on request. HART ™ protocol on request.

Serie-CU

 Water treatment and distribution, pharmaceutical, chemical and paper industry. Heating-cooling circuits, swimming pools and irrigation systems, fire protection installation, automotive industry and energy plants. Suitable for flow measurement of liquids such as sea water, kerosene, gas-oil, petrol, oils. Flow speed range: 0,2 … 12 m/s.  Accuracy:  +-1,5%. Diameters: DN80 … DN2000.  Transducers ingress protection: IP65. Converter ingress protection: IP65. Liquid temperature range: 0 … +80ºC. Power supply: 90 … 260 VAC 50 / 60 Hz. Power consumption:  < 5 W. Output: Flow and speed indication, Programmable analog output 4-20 mA proportional to flow rate, Volume totalizer, 2 programmable outputs for flow alarms.